Tyco partner is a is the distributor, and wholesale(r) of Tyco Products
 
   
TOTAL ACCESS 1500 MODULES
 Part" _ No.
Product

  TOTAL ACCESS 1500 MODULES

     Streaker card for testing continuity of both Total Access 1500 LIU network interfaces.

 

  TOTAL ACCESS 1500 MODULES

     Streaker card for testing continuity of all Total Access 1500 access module loop interfaces.

 

  TOTAL ACCESS 1500 MODULES

     Extended range OCU DP; 50 kft range.

 

  TOTAL ACCESS 1500 MODULES

     Single circuit FXO/DPT Gain Transfer module.

 

  TOTAL ACCESS 1500 MODULES

     For use in Total Access 1500 integrated access devices. Subrate, 19.2, 56, and 64 kbps Clear Channel operation; error correction, zero code suppression, and latching loopback. Data port can be optioned to operate as a DSO DP or as a Clear Channel Unit (CCU). Switched 56 Tandem functionality. Logic level test access.

 

  TOTAL ACCESS 1500 MODULES

     For use in Total Access 1500 integrated access devices. Subrate, 19.2, 56, and 64 kbps Clear Channel operation; error correction, zero code suppression, and latching loopback. Data port can be optioned to operate as a DSO DP or as a Clear Channel Unit (CCU). Switched 56 Tandem functionality. Logic level test access.

 

  TOTAL ACCESS 1500 MODULES

     For use in Total Access 1500 integrated access devices. Subrate, 19.2, 56, and 64 kbps Clear Channel operation; error correction, zero code suppression, and latching loopback. Data port can be optioned to operate as a DSO DP or as a Clear Channel Unit (CCU). Switched 56 Tandem functionality. Logic level test access.

 

  TOTAL ACCESS 1500 MODULES

     Non-intrusive monitoring of received data. Loop Quality Monitor and A/B signaling options. Remotely provisionable. Performance Monitoring using Digital System-6. Meets the requirements of NEBS Level 3 and UL 1950. Industry-leading 10-year warranty.

 

  TOTAL ACCESS 1500 MODULES

     The module provides the interface between a DS0 timeslot of the T-carrier data stream and the 4-wire metallic loop to the customer. The OCU DP will interoperate over the carrier system with another OCU DP, DS0 DP, DS0 cross-connect system, or switch, and can be located in an end office, hub office, intermediate office, or remote digital terminal system.

 

  TOTAL ACCESS 1500 MODULES

     FXO/DPT operating modes. Nominal 600 ohm or 900 ohm +2.16mF 2-Wire VF Interface with DC isolation. Provides PCM voice interface(digital), with -law 255 data access encoding/decoding. Loop start, ground start, and wink start signaling modes and operation. Digital loopback towards network. Meets the requirements of NEBS Level 3, UL 1950, and PUB43801.

 

  TOTAL ACCESS 1500 MODULES

     Dual independent FXS/DPOs on a single card. Provides an individual analog voice interface. Supports ground start, loop start, PLAR, DPO, and tandem. Long loop capability 1250 ohms (nominal). Hot swappable. V.90 modem compliant.

 

  TOTAL ACCESS 1500 MODULES

     Two independent DC-isolated 4-wire VF channel interfaces. Extended operating temperature range from -40°C to +65°C. TLP transmit input range of +5.0 to -16.0 dBm in 0.1 dB increments. TLP receive output range of +8.5 to -9.5 dBm in 0.1 dB increments. Supports configurations for Sink, Source or No Sealing Current. Provisioning by craft interface or Site Manager. Digital Loopback and 1004 Hz DRS Tone Tests via craft port or Site Manager. NEBS Level 3 compliant.

 

  TOTAL ACCESS 1500 MODULES

     Provides two independent 2-wire Voice Frequency (VF) channels. Nominal 600 ohms or 900 ohms?(+2.16 ?F). 2-wire VF interface with DC isolation. FXS Loop and Ground Start, DPO, Tandem, PLAR D3, PLAR D4 and FX Ringdown operating modes. CLASS compatible (Caller ID, Forward Disconnect, and Distinctive Ringing TR 57 compliant). Up to 6 dB of single-ended gain transfer. Extended operating temperature range from -40°C to +65°C. Backplane PCM voice interface.

 

  TOTAL ACCESS 1500 MODULES

     4-wire FXO module for the Total Access 1500.

 

  TOTAL ACCESS 1500 MODULES

     Two independent DC-isolated 4-wire VF channel interfaces. Supports 4-state FXS Ground and Loop Start signaling; 150, 600 and 1200 ohms input/output termination impedance; loaded and non-loaded cable types; Build Out Resistance (BOR) option to lower the DC loop current for short loop applications. Extended operating temperature range from -40°C to +65°C. Provisioning by craft interface or Site Manager. Digital Loopback, 1004 Hz DRS Tone, Network Hook, and Customer Ringing Tests via craft port or Site Manager. NEBS Level 3 compliant.

 

  TOTAL ACCESS 1500 MODULES

     Quad circuit COT POTS access module for the Total Access 1500. Supports MLT.

 

  TOTAL ACCESS 1500 MODULES

     Dual circuit COT P-phone access module for the Total Access 1500. This card is used in universal configurations.

 

  TOTAL ACCESS 1500 MODULES

     Dual circuit RT P-phone access module for the Total Access 1500. This card is used in both integrated and universal configurations.

 

  TOTAL ACCESS 1500 MODULES

     Dual circuit coin access module for the Total Access 1500. This card is used in universal configurations.

 

Home | Products | Order Forms | Support | Company
Terms of Sale | Privacy Policy | Contact Us | Our Partners | Search
An Industrial Partner 1999-2002. All rights reserved.

Adtran Articles catalogue

adtranpartner.com v 4_2